Estimation of Potential Outage Risk Evaluation of System using Performance Indices

Authors

  • Manjula B. G. Research Scholar, Department of Electrical and Electronics Engineering, Sapthagiri College of Engineering Bengaluru, Visvesvaraya Technological University Belagavi, India.
  • G. Raghavendra Associate Professor, Department of Electrical and Electronics Engineering, Sapthagiri College of Engineering Bengaluru, Visvesvaraya Technological University Belagavi, India

Keywords:

System Security, Contingency Analysis, State Estimation, Phasor Measurement Unit

Abstract

Primary concern of power system is economical operation, but an equally defensive factor is the desire to maintain security. It is imperative to study the state of system by outage analysis and monitor its impact in advance to minimize the occurrence of cascaded disruptions. In power flow analysis the possibility of any error in measurement is not considered assuming all values as accurate. Due consideration is taken to minimize these errors adopting weighted Least square state estimation method incorporating synchronized PMU measurements. Overall severity index is the guideline selected in evaluating the stress on IEEE 5 and IEEE 14 bus systems. Highest indexed events are ranked on the top indicating too troublesome conditions leading the system towards risk.

Downloads

Download data is not yet available.

References

Harisha K, “A Review on Contingency Analysis Methods of Electrical Power System,” International Journal of Advanced Science and Technology, vol. 29, pp. 4210-4222, 2020.

Chandrashekhar S. Hiwarkar, "Power System Security of IEEE-14 Bus with Contingency Analysis," International Journal of New Innovations in Engineering and Technology, vol. 12 , no. 3, pp. 8-14, December 2019.

Rohini G D, "Transmission Line Contingency Analysis in Power system using Fast Decoupled Method for IEEE-14 bus Test system," International Journal of Innovative Science, Engineering & Technology , vol. 2, no. 4, pp. 991-994, April 2015.

Riccardo AndreonI, "Tri-Objective Optimal PMU Placement Including Accurate State Estimation: The Case of Distribution Systems," IEEE Access, vol. 9, pp. 62102-62117, 21 April 2021.

Zhang Meng, “False data injection attacks against smart grid state estimation:,” Science China Technological Sciences, vol. 62, no. 12, December 2019 .

Chathura Thilakarathne, “Real-time voltage stability assessment using phasor measurement units: Influence of synchrophasor estimation algorithms,” Electrical Power and Energy Systems, Elsevier Ltd, pp. 1-13, 10 February 2020.

R. Muzzamel, "Design and Power Flow Analysis of Electrical System using Electrical Transient and Program Software," Energy and Power Engineering, vol. 11, pp. 186-199, April 2019.

Anamika Dubey, "SCADA and PMU Measurement Based Methods for Robust Hybrid State Estimation," Electric Power Components and Systems, vol. 47, pp. 849-860, 25 July 2019..

M. Liu, “State estimation in a smart distribution system,” HKIE Transactions, vol. 24, no. 1, pp. 1-8, 30 March 2017.

Mohammad Shoaib Shahriar, “Optimization of Phasor Measurement Unit (PMU) Placement in Supervisory Control and Data Acquisition (SCADA)-Based Power System for Better State-Estimation Performance,” Energies , vol. 11, no. 570, pp. 1-15, 6 March 2018.

Junwei YANG, "A sparse recovery model with fast decoupled solution for distribution state estimation and its performance analysis," Journal of Modern Power Systems and Clean Energy, vol. 7, no. 6, p. 1411–1421, 9 May 2019.

Yoshiaki Matsukawa, "Voltage Stability Index Calculation by Hybrid State Estimation Based on Multi Objective Optimal Phasor Measurement Unit Placement," Energies, vol. 12, 12 July 2019.

G. H. Aleksandar Jovicic, "Linear state estimation and bad data detection for power systems with RTU and PMU measurements," The Institution of Engineering and Technology, vol. 14, no. 23, pp. 5675-5684, 22 October 2020.

J. Chen, "Placement of PMUs to Enable Bad Data Detection in State Estimation," IEEE Transctions on Power Systems, vol. 21, no. 4, pp. 1608-1615, November 2006.

Rachana Choudhary, “Identification of Critical Transmission Line for Voltage Collapse Using Deterministic Indices in Ieee-14 Bus System,” International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, vol. 5, no. 7, pp. 6261-6268, July 2016.

Mostafa Gholami, "Static security assessment of power systems: A review," Trans Electr Energ Syst., pp. 1-23, 17 March 2020.

Hrvoje Bulat, “Enhanced Contingency Analysis—A Power System Operator Tool,” Energies, pp. 1-21, 10 February 2021.

Ahmed R, "Power Systen Security Assessment under N-1 and N-1-1 ContingencyConditions," International Journal of Engineering Research and Technology, vol. 12, no. 11, pp. 1854-1863, November 2019.

Dhanshree. Y. Shende, “Load Flow Analysis of IEEE 14 Bus Systems in Matlab by Using Fast Decoupled Method,” International Research Journal of Engineering and Technology, vol. 07 , no. 2, pp. 888-891, February 2020.

Downloads

Published

29.01.2024

How to Cite

B. G., M. ., & Raghavendra, G. . (2024). Estimation of Potential Outage Risk Evaluation of System using Performance Indices. International Journal of Intelligent Systems and Applications in Engineering, 12(13s), 41–49. Retrieved from https://ijisae.org/index.php/IJISAE/article/view/4566

Issue

Section

Research Article